Products
products center
SWMP Motor Protector Controller
SWMP motor protector controller is a new type of motor protection device carefully developed by our company. The device is specially designed to meet the needs of diversified industrial environments such as electric power, petrochemical, light industry, coal, paper and steel. It is in AC220V/AC380V/AC660V, 50Hz/60Hz motor control system to provide more comprehensive monitoring and protection.
Product Details
Product overview
SWMP motor protector controller is a new type of motor protection device carefully developed by our company. The device is specially designed to meet the needs of diversified industrial environments such as electric power, petrochemical, light industry, coal, paper and steel. It is in AC220V/AC380V/AC660V, 50Hz/60Hz motor control system to provide more comprehensive monitoring and protection.
SWMP motor protector controller adopts advanced modular design concept, which is composed of main control unit, transformer, display unit and connecting line, which ensures the convenience of product installation and maintenance; it has built-in comprehensive protection functions, including short circuit, overload, locked rotor, phase failure, imbalance, leakage, grounding, overvoltage and undervoltage, etc., to ensure that the motor can operate safely and stably even under extreme conditions; in addition, the product provides comprehensive power measurement function, real-time monitoring of key parameters such as current, voltage and power, evaluation of the heat capacity of the motor during operation, and necessary protection according to user settings to prevent the motor from overheating and damage.
The SWMP Motor Protector Controller's communication interface supports Modbus-RTU, Modbus-TCP and Profibus-DP protocols, seamlessly integrating into existing industrial automation networks for efficient remote monitoring and control. The optional LCD Chinese display shows the working status and related parameters of the motor in an intuitive and friendly way, which greatly improves the user experience.
To meet the specific needs of different users, SWMP motor protector controllers provide a range of flexible configuration options. Users can select the most matching current class and transformer model based on the specifications and application scenarios of the motor. In addition, the product provides an independent special transformer selection guide, motor rated power and rated current comparison table, to provide users with a clear product selection reference.
Product Features
Comprehensive protection: Provide a variety of motor protection functions including short circuit, overload, locked rotor, phase failure, imbalance, leakage, grounding, overvoltage, undervoltage, phase sequence, etc.
Rich measurement function: it can measure current, voltage, power and other electricity, and has thermal capacity monitoring to ensure the comprehensive monitoring of motor running state.
Flexible communication: support Modbus-RTU, Modbus-TCP (optional) and Profibus-DP (optional) and other communication protocols, easy to integrate with a variety of automation systems.
Flexible configuration: Users can choose leakage protection or grounding protection according to their needs, which increases the applicability and flexibility of the product.
Abundant input and output interfaces: 7 passive switching inputs and 5 relay outputs meet complex control requirements.
Intuitive display: Optional LCD Chinese display, easy for users to intuitively understand the working state of the motor and related parameters.
Modular design: split design of display, host and transformer, easy to install and maintain.
Wide applicability: Suitable for motors with a variety of rated operating voltages and frequencies to meet the needs of different applications.
It can be used with a variety of components, and can be used with AC contactors, soft starters, molded case circuit breakers and other components to provide comprehensive motor circuit protection.
Background system solutions: Support professional monitoring and fault solutions through the background system.
Electrical parameters and electromagnetic compatibility: with detailed electrical parameter specifications and electromagnetic compatibility standards to ensure product stability and reliability.
Environmental adaptability: The product design takes into account different working environments and storage conditions, including temperature and humidity ranges, as well as installation altitude restrictions.
Main functions
|
Protection function |
Starting mode |
Measurement function |
Maintenance function |
|
|
Protection mode |
|
|
|
Starting timeout protection |
Direct starting |
three-phase current |
Current Running Time |
|
Overload protection |
Bidirectional starting |
three-phase voltage |
Current Parking Time |
|
Stall-rotor protection |
Y/△ Starting |
Power, power factor, frequency |
Cumulative Running Time |
|
Lack of phase protection |
Autotransformer starting |
Heat capacity |
Starting current |
|
Unbalanced protection |
soft start |
Electric energy |
Starting time |
|
underload protection |
Two-speed starting |
Leakage/earth current |
Operation status |
|
Leakage/earth protection Overvoltage protection Undervoltage protection Short circuit protection phase sequence protection |
|
|
Input and output status Event Logging Alarm Query Running status |
|
External fault |
|
|
|
|
te time protection Underpower protection |
|
|
|
Electrical parameters
|
Function |
Project |
Content |
|
Transformer rating |
In |
1,5,25,100,250,500,820 |
|
Motor set current range |
Ie |
1A(0.1A~1A),5A(1A~5A),25A(5A~25A),100A(25A~100A),250A(100A~250A),500A(250A~500A),820A(400~820A) |
|
Voltage rating |
Ue |
AC220/380/660V |
|
Leakage rating |
Inm |
1A |
|
Starting timeout protection |
Action enable |
0FF ON |
|
Short circuit protection |
Action value |
600%~1000%Ie+OFF |
|
Delay time |
0~60.00s |
|
|
Stall-rotor protection |
Range of action value |
200%Y~1000%Y+Y |
|
Delay time |
0.5s~60s |
|
|
Protection Execution Mode |
Alarm/Trip |
|
|
Inverse time overload protection |
Thermal coefficient of motor |
10,24,60,130,180,260,380,570,760,960,1120,1280 |
|
cold-hot curve ratio |
20%~100% |
|
|
Cooling time |
5min ~ 1080min, step difference 1min |
|
|
Protection Execution Mode |
Alarm/Trip |
|
|
Fixed time overload protection |
Range of action value |
100%Y~1000%Y+Y |
|
Delay time |
0.1s~60s |
|
|
Protection Execution Mode |
Alarm/Trip |
|
|
te time protection |
Action enable |
OFF ON |
|
te time |
1.0s~12.8s |
|
|
Protection Execution Mode |
Alarm/Trip |
|
|
Unbalanced protection |
Range of action value |
5%~60%+OFF |
|
Delay time |
0.5s~60s |
|
|
Protection Execution Mode |
Alarm/Trip |
|
|
Lack of phase protection |
Action enable |
OFF ON |
|
Delay time |
0.1s~60s |
|
|
Undervoltage protection |
Range of action value |
30%Ue~95%Ue+OFF |
|
Delay time |
0.1s~60s |
|
|
Protection Execution Mode |
Alarm/Trip |
|
|
Overvoltage protection |
Range of action value |
105%Ue~150%Ue+OFF |
|
Delay time |
0.1s~60s |
|
|
Protection Execution Mode |
Alarm/Trip |
|
|
underload protection |
Range of action value |
20% CH~90% C++L |
|
Delay time |
0.1s~60s |
|
|
Protection Execution Mode |
Alarm/Trip |
|
|
Leakage/earth protection |
Range of action value |
1~100%+OFF |
|
Leakage start delay time |
0s~60.00s |
|
|
Leakage operation delay time |
0s~60.00s |
|
|
shear coefficient |
0 (hardware measurement),1.5~6.0,OFF (ground current is automatically calculated, the operating characteristic is fixed time limit when OFF, otherwise it is inverse time limit) |
|
|
Protection Execution Mode |
Alarm/Trip |
|
|
phase sequence protection |
Protection Execution Mode |
0FF ON |
|
Delay time |
0~60.0 |
|
|
Underpower protection |
Range of action value |
20% CH~90% C++L |
|
Delay time |
0s~60s |
|
|
Protection Execution Mode |
Alarm/Trip |
|
|
External fault |
Action enable |
0FF ON |
|
Delay time |
0s~60s |
|
|
Protection Execution Mode |
Alarm/Trip |
|
|
AC contactor fault |
Action enable |
0FF ON |
online message